APPLICATIONS
- Architectural - Commercial - Residential
COLORS
- Kynar 500® Coated
- Numerous Energy Star Rated Colors
SLOPE
- 2:12 or Greater
SPECIFICATIONS
- 24 Gauge Steel, Aluminum or Copper
- Up to 20" Wide (Drop on smaller widths)
- Clip Relief & Stiffening Ribs - FREE
- On-Site Production Available
SUBSTRATE
- Solid Wood Decking (15/32” Minimum)
FLASHING
- 26 or 24 Gauge (Mill Finish)
- 24 Gauge (Kynar 500® Coated)
- Aluminum (Kynar 500® Coated)
- Copper
FLORIDA APPROVALS
FL # 21423.5 - Sunlast Metal “Palm Beach Series”
- Approved for use in HVHZ
- Steel over Plywood Deck
METHOD 1
Clip Spacing: 24” Panel Seem: 90° Design Pressure: -93.5 psf
METHOD 2
Clip Spacing: 6" Panel Seem: 90° Design Pressure: -101 psf
METHOD 3
Clip Spacing: 6" Panel Seem: 180° Design Pressure: -112 psf
FL # 21423.6 - Sunlast Metal “Palm Beach Series”
- Approved for use in HVHZ
- Aluminum over Plywood Deck
METHOD 1
Clip Spacing: 24” Panel Seem: 90° Design Pressure: -63.5 psf
METHOD 2
Clip Spacing: 24” Panel Seem: 90° Design Pressure: -86 psf
METHOD 3
Clip Spacing: 6” Panel Seem: 180° Design Pressure: -131 psf
Association Approvals
FL # 18712.2 - Pac-Clad- Pac-150
- Approved for use in HVHZ
- Aluminum over Plywood Deck
FL # 18712.3 - Pac-Clad- Pac-150
- Approved for use in HVHZ
- Steel over Plywood Deck
MIAMI-DADE APPROVALS
Association Approvals
NOA # 15-0212.05 - Pac-Clad- Pac-150
- Approved for use in HVHZ
- Steel over Plywood Deck
NOA # 15-0212.06 - Pac-Clad- Pac-150
- Approved for use in HVHZ
- Aluminum over Plywood Deck
NOA # 17-0405.02 - Englert 1300
- Approved for use in HVHZ
- Steel over Plywood Deck
NOA # 17-0405.04 - Englert 1300
- Approved for use in HVHZ
- Aluminum over Plywood Deck
NOA # 17-0405.10 - Englert 1300
- Approved for use in HVHZ
- Zinc over Wood Deck
NOA # 17-0405.12 - Englert 1300
- Approved for use in HVHZ
- Copper over Wood Deck
NOA # 17-0405.13 - Englert 1300
- Approved for use in HVHZ
- Aluminum over Steel Deck
NOA # 17-0405.14 - Englert 1300
- Approved for use in HVHZ
- Steel over Steel Deck